• Battery Simulator
  • video

Battery Simulator

    Product overview

    The ZBD-S series battery simulator features high-precision DC output characteristics with excellent dynamic response capabilities, along with bidirectional energy conversion functionality. Utilizing full digital control, it delivers high accuracy, rapid response, and a wide output adjustment range. This battery simulator can simulate charging/discharging characteristics of various battery types. It is primarily used for testing electric vehicle drive motors (controllers), PCS (Power Conversion Systems) (energy storage inverters), bidirectional EV chargers, and battery pack charge/discharge operations.

     

    Product features:

    Built-in AC isolation transformer +LC AC/DC filter, input and output electrical isolation;

    Use Infineon high voltage IGBT module two-stage conversion, pure digital frequency

    isolation power supply;

    Energy can be fed back to the grid: it has both power supply and load characteristics;

    The three-level/carrier phase shift circuit is adopted on the DC/DC side to make the DC

    output side more accurate and the ripple smaller;

    It can achieve the characteristics of wide voltage range, high precision and fast dynamic response;

    Output has constant voltage, constant voltage current limiting, constant current, constant

     power, constant resistance mode;

    It has the power battery simulation function, and the simulated battery internal resistance

     can be freely determined according to the user's working conditions.

     

    App industries

    It is used in the test of electric vehicle drive motor (controller), PCS (bidirectional energy storage inverter), electric vehicle bidirectional charger, battery pack charge and discharge test and other fields.


     unit type

    ZBD-S40

    -800/24-100-1

    ZBD-S60

    -1000/24-200-

    ZBD-S80

    -1000/24-300-

    ZBD-S150

    -1000/24-500-

    ZBD-S300

    -1000/24-800-

    ZBD-S400

    -1000/24-900-

    ZBD-S500

    -1000/24-1000-1

    ZBD-S600

    -1000/24-1200-1

     power rating

    40kW

    60kW

    80kW

    150KW

    300kW

    400KkW

    500kW

    600kW

     rated current

    100A

    200A

    300A

    500A

    800A

    900A

    1000A

    1200A

     rated voltage

    400V

    300V

    265V

    300V

    375V

    445V

    500V

    500V

     voltage range

    24-800V

    24-1000V (standard) /24-1200V (optional)/48-1500V optional

    Input exchange indicators

     

    Power supply type

    Three phase four wire +PE

     voltage range

    400V(±15%)

     frequency range

    50Hz(±10%)

     power factor

    20.99

     current harmonics

    THDi3%

    Output DC characteristics

     

     number of channels

    Single channel/bis channel (optional)

     peak power

    1.2 Pe(60s)

     peak point current

    12 le(60%)

    Source effect

    s0.1%FS

    The negative side effect

    E0.1%FS

     voltage accuracy

    0.1S

    Current accuracy

    50.16FS

     voltage ripple

    0.2%FS

     response time

    3ms (10W-90% sudden load)

     switching period

    6ms (switching-90-+90%)

     device efficiency

    94%

    Feedback characteristics

     

    Voltage range of the grid

    360-440V

    Frequency range of power grid

    47-53Hz

     power factor

    099

     current harmonics

    THDi63%

    Feedback power

    Support full range power feedback

     system function

     

     work pattern

    Constant voltage/constant current/constant power

    Battery simulation

    The parameters such as single battery capacity, voltage, series number, parallel number, SOC, internal resistance and charging rate of various types of batteries can be set

     isolation method

    Power frequency isolation transformer

    Remote compensation

    Adaptive compensation line voltage drop

     defencive function

    Overvoltage, undervoltage, phase loss, overcurrent, short circuit, overload, overheating, emergency stop and other protection

    Display and communications

     

    Local operation

    LCD display screen

    Yunhe Communications

    RS 485/LAN/CAN

     protocol

    Standard Modbus RTU/Modbus TCP/IP/CAN2.0

    Safety performance

     

     compression strength

    2000Vdc/60s/ no breakdown

     insulation resistance

    =20MQ(500Vdc)

     earthing resistance

    5100m

     noise

    65dB/A)

     service environment

     work environment

    The ambient temperature is-20-45 and the relative humidity is 0-95%. It can work continuously for 24 hours

     cooling-down method

    Fan forced air cooling

     levels of protection

    IP21

     above sea level

    5000m@>2000m reduced use

    Size (W-D+H) mm

    650-650-1600

    (including mobile wheels)

    1000-1000-1860

    (including mobile wheels)

    1000-1000-1860

    (including mobile wheels)

    1000-1000-1860    18001000

    (With mobile wheels) -1840

    1800-1000

    *1840

    2000-1240

    ·2080

    2000-1240 *2080



    Get the latest price? We will reply as soon as possible (within 12 hours)