• Manganese Electrolysis Rectifier Cabinet
  • video

Manganese Electrolysis Rectifier Cabinet

    The manganese electrolysis rectifier unit is a key piece of equipment in the manganese smelting and purification process. The compatibility of the rectifier equipment significantly impacts the quality of electrolytic manganese and the cost of electricity. A complete rectifier unit includes a rectifier cabinet, digital control cabinet, rectifier transformer, pure water cooler, DC sensors, and DC switches. It is typically installed indoors near the electrolytic cell, cooled by pure water, and has input voltages of 35KV, 10KV, etc.

    Manganese electrolysis rectifier units are key equipment in the manganese smelting and purification process. The compatibility of the rectifier equipment significantly impacts the quality and power consumption cost of electrolytic manganese. A complete rectifier system includes a rectifier cabinet, digital control cabinet, rectifier transformer, pure water cooler, DC sensors, and DC switches. It is typically installed indoors near the electrolytic cell, using pure water cooling, and has input voltages of 35KV, 10KV, etc.

      

    Manganese Electrolysis Thyristor Rectifier Equipment

     

    I. Applications

    This series of rectifier cabinets is mainly used for various types of rectifier equipment and automated control systems in the electrolysis of non-ferrous metals such as aluminum, magnesium, manganese, zinc, copper, and lead, as well as chloride salts. It can also serve as a power supply for similar loads.

     

    II. Main Cabinet Features

     

    1. Electrical Connection Type: Generally selected based on DC voltage, current, and grid harmonic tolerances, there are two main categories: double-anti-star and three-phase bridge, as well as four different combinations of six-pulse and twelve-pulse connections available.

     

    2. High-power thyristors are used to reduce the number of parallel components, simplifying the cabinet structure, reducing losses, and facilitating maintenance.

     

    3. Components and fast-fusing copper busbars use specially designed circulating water circuit profiles for ample heat dissipation and improved component lifespan.

     

    4. Component press-fitting adopts a typical design for balanced fixed force and double insulation.

     

    5. Imported reinforced transparent soft plastic tubing is used for internal water connections, resistant to hot and cold temperatures and with a long service life.

     

    6. Component radiator faucets undergo special treatment for corrosion resistance.

     

    7. The cabinet is machined using fully CNC machine tools and features overall powder coating for an aesthetically pleasing appearance.

     

    8. Cabinets are generally available in indoor open, semi-open, and outdoor fully sealed types, with inlet and outlet wiring designed according to user requirements.

     

    9. This series of rectifier cabinets uses a digital industrial control trigger control system to ensure the equipment...

     

    III. Technical Characteristics

     

    1. Regulator: Digital regulators offer flexible and variable control methods and stable characteristics, while analog regulators provide rapid response. Both employ DC current negative feedback control, achieving a current stabilization accuracy better than ±0.5%. 2. Digital Trigger: Outputs 6-phase or 12-phase trigger pulses, with a double narrow pulse pattern spaced 60° apart. It features a strong trigger waveform, phase asymmetry ≤ ±0.3°, phase shift range 0~150°, and single-phase AC synchronization. High pulse symmetry is achieved.

     

    3. Operation: Touch key operation enables start-up, shutdown, and current adjustment.

     

    4. Protection: Includes no-current start, two-stage DC overcurrent alarm protection, feedback signal loss protection, water pressure and temperature over-limit protection, process interlock protection, and operating control angle over-limit indication. It can also automatically adjust the transformer tap position based on the control angle.

     

    5. Display: LCD display shows DC current, DC voltage, water pressure, water temperature, oil temperature, and control angle.

     

    6. Dual-channel product: During operation, the two channels serve as hot standby for each other, allowing for maintenance without shutdown and switching without (current) disturbance. 7. Network Communication: Supports multiple communication protocols including Modbus, Profibus, and Eathernet.

     

    Voltage Specifications:

    16V 36V 75V 100V 125V 160V 200V 315V 400V 500V 630V 800V 1000V 1200V 1400V

     

    Current Specifications:

    300A 750A 1000A 2000A 3150A 5000A 6300A 8000A 10000A 16000A 20000A 25000A 31500A 40000A 50000A

    63000A 80000A 100000A 120000A 160000A

     

    Function Description

    Small Dummy Load: A piece of heating element is connected to replace the actual load, ensuring a DC current of 10-20A at the rated DC output voltage.

     

    Intelligent Thermal Redundancy Control System: Two CNC controllers, interconnected with thermal redundancy ports, operate in parallel and coordinately, eliminating any control contention or exclusion. Seamless switching between master and slave controllers.

     

    If the master controller fails, the redundant controller automatically and seamlessly switches to master, truly achieving dual-channel thermal redundancy control. This significantly improves the reliability of the control system.

     

    Seamless Master/Redundancy Switching: Two ZCH-12 control systems with mutual thermal redundancy can be manually configured to determine which controller acts as master and which as slave. The switching process is seamless.

     

    Redundancy Switching: If the master controller fails due to an internal fault, the redundant controller automatically and seamlessly switches to master.

     

    Pulse Adaptive Main Circuit: When a small dummy load is connected to the main circuit, and the voltage feedback amplitude is adjusted within the range of 5-8 volts, the ZCH-12 automatically adjusts the pulse start point, end point, phase shift range, and pulse distribution sequence to make the pulse phase shift adaptive to the main circuit. No manual intervention is required, making it more accurate than manual setting.

     

    Pulse Clock Number Selection: By selecting the pulse clock number, the pulse can adapt to the main circuit phase and correctly shift phase.

     

    Pulse Phase Fine-tuning: Through pulse phase fine-tuning, the pulse can be precisely aligned with the main circuit phase shift, with an error ≤1°. The fine-tuning value range is -15° to +15°.

     

    Two-Group Pulse Phase Adjustment: Changes the phase difference between the first and second groups of pulses. The adjustment value is zero, and the phase difference between the first and second groups of pulses is 30°. The adjustment value range is -15° to +15°.

     

    Channel 1F is designated as one group of current feedback. Channel 2F is designated as two groups of current feedback.

     

    Automatic Current Sharing: The ZCH-12 automatically adjusts based on the deviation of the first and second groups of current feedback without manual intervention. Manual current sharing is achieved manually by adjusting the current sharing between the star and two groups.

     

    Seamless switching: The power output remains unchanged during switching.

     

    Emergency stop function: When the FS terminal is shorted to the 0V terminal, ZCH-12 immediately stops sending trigger pulses. Leaving the FS terminal floating allows trigger pulses to be sent.

     

    Soft start function: When ZCH-12 is powered on, after self-test, the output slowly climbs to the given output. The standard soft start time is 5 seconds. Custom time is adjustable.

     

    Zero return protection function: When ZCH-12 is powered on, after self-test, if the given value is not zero, no trigger pulse is output. Normal operation resumes when the given value returns to zero.

     

    ZCH-12 software reset: ZCH-12 is reset by executing a software program command.

     

    ZCH-12 hardware reset: ZCH-12 is reset via hardware.

     

    Phase shift range selection: Range 03. 0: 120°, 1: 150°, 2: 180°, 3: 90°

     

    Permanent Parameter Saving: Control parameters changed during CNC debugging are saved in RAM and will be lost during power outages. To permanently save the debugged control parameters: ① Set bits 1-8 of SW1 and SW2 to OFF, OFF, OFF, OFF, OFF, ON, OFF, OFF to enable saving;

     

    Enable the permanent parameter saving function; ③ Set bits 1-8 of SW1 and SW2 to OFF to disable saving.

     

    PID Parameter Auto-tuning: The controller automatically measures load characteristics to obtain the optimal algorithm for the load. This is more precise than manual adjustment. For special loads where load characteristics are related to load conditions and vary greatly, PID can only be manually tuned.

     

    PID Controller Selection:

     

    PID0 is a dynamic, fast PID controller, suitable for resistive loads.

     

    PID1 is a medium-speed PID controller with excellent overall automatic adjustment performance, suitable for resistive-capacitive and resistive-inductive loads.

     

    PID2 is suitable for controlled objects with large inertia, such as voltage regulation of capacitive loads and current regulation of inductive loads.

     

    PID3 to PID7 are manual PID controllers, allowing manual adjustment of the P, I, and D parameter values. PID8 and PID9 are customized for special loads.


    Get the latest price? We will reply as soon as possible (within 12 hours)